Title: | Comparison of LHC collimation setups with manual and semi-automatic collimator alignment |
Authors: | Valentino, Gianluca Sammut, Nicholas Demicoli, Marija Bruce, Roderik Wolfgang Assmann, Ralph Burkart, Florian Deboy, Daniel Redaelli, Stefano Rossi, Adriana Wollmann, Daniel |
Keywords: | Collimators (Optical instrument) Large Hadron Collider (France and Switzerland) |
Issue Date: | 2011 |
Publisher: | IPA |
Citation: | Valentino, G., Sammut, N., Cauchi, M., Bruce, R., Wolfgang Assmann, R., Burkart, F.,… Wollmann, D. (2011). Comparison of LHC collimation setups with manual and semi-automatic collimator alignment. International Particle Accelerator Conference 2011, San Sebastian. 3771-3773. |
Abstract: | The LHC collimation system beam-based alignment procedure has recently been upgraded to a semi-automatic process in order to increase its efficiency. In this paper, we describe the parameters used to measure the accuracy, stability and performance of the beam-based alignment of the LHC collimation system. This is followed by a comparison of the results at 450 GeV and 3.5 TeV with (1) a manual alignment and (2) with the results for semi-automatic alignment. |