Title: | How to achieve balloon stability in aortic valvuloplasty using rapid ventricular pacing |
Authors: | Mehta, C. Shebani, S. Grech, Victor E. DeGiovanni, Joseph V. |
Keywords: | Heart defects, Congenital Heart catheterization Electrophysiologic techniques, Cardiac Cardiac pacing, Artificial Aortic valve -- Stenosis |
Issue Date: | 2004 |
Publisher: | Images in Paediatric Cardiology |
Citation: | Images in Paediatric Cardiology. 2004, Vol.6(4), p. 31-37 |
Abstract: | Balloon aortic valvuloplasty is now the treatment of choice for congenital aortic stenosis. Balloon stability may be difficult to achieve and this may result in a suboptimal result or even valve damage. We describe the technique of rapid ventricular pacing as a safe and effective option for achieving balloon stability during aortic valvuloplasty. |