dc.contributor.authorSun, Y.-
dc.contributor.authorDearnley, Peter A.-
dc.contributor.authorMallia, Bertram-
dc.date.accessioned2022-09-02T09:35:18Z-
dc.date.available2022-09-02T09:35:18Z-
dc.date.issued2017-
dc.identifier.citationSun, Y., Dearnley, P. A., & Mallia, B. (2017). Response of duplex Cr (N)/S and Cr (C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(6), 1503-1513.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/101408-
dc.description.abstractTwo duplex coatings, Cr(N)/S and Cr(C)/S, were deposited on 316 L stainless steel by magnetron sputtering. The effectiveness of these duplex coatings in improving the tribocorrosion behavior of medical alloys under elastic contact conditions has been demonstrated in a recent publication. The present work focused on the response of these duplex coatings to tribocorrosion under plastic contact conditions. Tribocorrosion tests were conducted in 0.89% NaCl solution at 378C at an initial contact pressure of 740 MPa and under unidirectional sliding conditions for sliding duration up to 24 h. The results showed that during sliding in the corrosive solution, the duplex coatings were plastically deformed into the substrate to a depth about 1 lm. The Cr(C)/S duplex coating had sufficient ductility to accommodate the deformation without cracking, such that it was worn through gradually, leading to the gradual increase in open circuit potential (OCP) and coefficient of friction (COF). On the other hand, the Cr(N)/S duplex coating suffered from cracking at all tested potentials, leading to coating blistering after prolonged sliding at OCP and stable pit formation in the substrate beneath the coating at applied anodic potentials.en_GB
dc.language.isoenen_GB
dc.publisherWiley Periodicals, Inc.en_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectStainless steelen_GB
dc.subjectTribo-corrosionen_GB
dc.subjectCoating processesen_GB
dc.subjectFrictionen_GB
dc.titleResponse of duplex Cr(N)/S and Cr(C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditionsen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1002/jbm.b.33690-
dc.publication.titleJournal of Biomedical Materials Research Part B: Applied Biomaterialsen_GB