dc.contributor.author | Sun, Y. | - |
dc.contributor.author | Dearnley, Peter A. | - |
dc.contributor.author | Mallia, Bertram | - |
dc.date.accessioned | 2022-09-02T09:35:18Z | - |
dc.date.available | 2022-09-02T09:35:18Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Sun, Y., Dearnley, P. A., & Mallia, B. (2017). Response of duplex Cr (N)/S and Cr (C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(6), 1503-1513. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/101408 | - |
dc.description.abstract | Two duplex coatings, Cr(N)/S and Cr(C)/S, were deposited on 316 L stainless steel by magnetron sputtering. The effectiveness of these duplex coatings in improving the tribocorrosion behavior of medical alloys under elastic contact conditions has been demonstrated in a recent publication. The present work focused on the response of these duplex coatings to tribocorrosion under plastic contact conditions. Tribocorrosion tests were conducted in 0.89% NaCl solution at 378C at an initial contact pressure of 740 MPa and under unidirectional sliding conditions for sliding duration up to 24 h. The results showed that during sliding in the corrosive solution, the duplex coatings were plastically deformed into the substrate to a depth about 1 lm. The Cr(C)/S duplex coating had sufficient ductility to accommodate the deformation without cracking, such that it was worn through gradually, leading to the gradual increase in open circuit potential (OCP) and coefficient of friction (COF). On the other hand, the Cr(N)/S duplex coating suffered from cracking at all tested potentials, leading to coating blistering after prolonged sliding at OCP and stable pit formation in the substrate beneath the coating at applied anodic potentials. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Wiley Periodicals, Inc. | en_GB |
dc.rights | info:eu-repo/semantics/openAccess | en_GB |
dc.subject | Stainless steel | en_GB |
dc.subject | Tribo-corrosion | en_GB |
dc.subject | Coating processes | en_GB |
dc.subject | Friction | en_GB |
dc.title | Response of duplex Cr(N)/S and Cr(C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.1002/jbm.b.33690 | - |
dc.publication.title | Journal of Biomedical Materials Research Part B: Applied Biomaterials | en_GB |
Appears in Collections: | Scholarly Works - FacEngMME |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Response_of_duplex_Cr(N)S_and_Cr(C)S_coatings_on_316L_stainless_steel_to_tribocorrosion_in_0.89_NaCl_solution_under_plastic_contact_conditions.pdf | 793.54 kB | Adobe PDF | View/Open |