Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/102816
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cortes, Arthur R. G. | - |
dc.contributor.author | Agius, Anne-Marie | - |
dc.contributor.author | No-Cortes, Juliana | - |
dc.date.accessioned | 2022-10-19T06:28:57Z | - |
dc.date.available | 2022-10-19T06:28:57Z | - |
dc.date.issued | 2022 | - |
dc.identifier.citation | Cortes, A. R. G., Agius, A. M., & No-Cortes, J. (2022). Factors Affecting Trueness of Intraoral Scans: An Update. Applied Sciences, 12(13), 6675. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/102816 | - |
dc.description.abstract | Background: Intraoral scanning (IOS) technologies have been constantly developed and improved. This systematic review aimed at assessing studies in the recent literature describing factors that influence the trueness of intraoral scans. Methods: Comparative in vitro and in vivo (i.e., interventional and observational) studies that quantitatively assessed the trueness of intraoral scans and that identified factors significantly affecting IOS trueness values were considered eligible for inclusion. The PUBMED and EMBASE databases were searched for articles published in the last two years (from February 2020 to February 2022). Data assessment and extraction were performed according to the guidelines of the PRISMA statement. Results: The present search strategy yielded 13 publications. An initial screening of the publications was performed using abstracts and key words, and after application of exclusion criteria, a total of nine studies were finally identified as eligible to be discussed. Several factors significantly affecting IOS were identified. Conclusions: Studies using current IOS technologies revealed that the device, scanning distance, operator experience, rescanning and post-processing scans, conditions of the preparations and presence of adjacent teeth are factors significantly affecting IOS trueness. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | MDPI AG | en_GB |
dc.rights | info:eu-repo/semantics/openAccess | en_GB |
dc.subject | Scanning systems -- Evaluation | en_GB |
dc.subject | Computer-aided design -- Software | en_GB |
dc.subject | Crowns (Dentistry) -- Post and care technique | en_GB |
dc.subject | Mouth -- Care and hygiene | en_GB |
dc.subject | Edentulous mouth | en_GB |
dc.title | Factors affecting trueness of intraoral scans : an update | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.3390/app12136675 | - |
dc.publication.title | Applied Sciences | en_GB |
Appears in Collections: | Scholarly Works - FacDenDS |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Factors_affecting_trueness_of_intraoral_scans.pdf | 403.09 kB | Adobe PDF | View/Open |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.