Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/103398
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGatt, Alexander-
dc.contributor.authorvan Veen, J. J.-
dc.contributor.authorBowyer, A.-
dc.contributor.authorWoolley, A. M.-
dc.contributor.authorCooper, P.-
dc.contributor.authorKitchen, S.-
dc.contributor.authorMakris, M.-
dc.date.accessioned2022-11-04T08:30:42Z-
dc.date.available2022-11-04T08:30:42Z-
dc.date.issued2008-
dc.identifier.citationGatt, A., Van Veen, J. J., Bowyer, A., Woolley, A. M., Cooper, P., Kitchen, S., & Makris, M. (2008). Wide variation in thrombin generation in patients with atrial fibrillation and therapeutic International Normalized Ratio is not due to inflammation. British Journal of Haematology, 142(6), 946-952.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/103398-
dc.description.abstractAtrial fibrillation (AF) is a common cardiac arrhythmia with a 5–20% annual risk of stroke. Warfarin reduces this risk by at least 60%. Despite adequate anticoagulation within the target International Normalized Ratio (INR) range of 2Æ0–3Æ0, some patients still experience thrombotic and bleeding events. It is now possible to assess the intensity of anticoagulation with automated thrombin generation (TG) tests, such as the calibrated automated thrombogram (CAT). These tests were compared and an inverse relationship was found between the INR and CAT in 143 elderly AF patients. There was equally good correlation between the concentration of factors II, VII, IX and X and the INR and TG parameters. The peak thrombin was most strongly associated with the concentration of prothrombin fragment 1 + 2 in plasma. There was wide variability in TG parameters in patients with identical INR values, sometimes up to a fourfold difference. This TG variability in individuals with the same INR is not due to inflammation, at least when the latter is measured as the concentration of factor VIII coagulant activity, von Willebrand factor antigen, high sensitivity C-reactive protein and fibrinogen. It was concluded that, although the TG and INR were closely correlated there was wide variability in peak thrombin and endogenous thrombin potential in patients within the INR therapeutic range, the cause of which remains unclear.en_GB
dc.language.isoenen_GB
dc.publisherWiley-Blackwell Publishing, Inc.en_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectAtrial fibrillation -- Risk factorsen_GB
dc.subjectThrombin -- Physiological effecten_GB
dc.subjectBlood coagulation factor VIIIen_GB
dc.subjectBlood coagulation testsen_GB
dc.subjectInternational Normalized Ratioen_GB
dc.titleWide variation in thrombin generation in patients with atrial fibrillation and therapeutic International Normalized Ratio is not due to inflammationen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1111/j.1365-2141.2008.07279.x-
dc.publication.titleBritish Journal of Haematologyen_GB
Appears in Collections:Scholarly Works - FacM&SPat



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.