dc.identifier.citationMifsud, A., Peelen, D., Brincat, P., Abela, S., Debattista, N., Laspina, S.,...Gatt, A. (2016). A feasibility study on the effects of Triton X-100 for the in vitro inactivation of Ebola virus on haematological assays. Journal of Clinical Pathology, 69(7), 637-642.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/103432-
dc.description.abstractAims: The aim of this study was to check the effect of Triton X-100 on various, commonly used haematology test parameters. Methods: Anonymised blood samples were treated with 10 mL of 10% Triton X-100 per 1 mL of blood. Treated and untreated samples were tested in parallel for blood film morphology, complete blood counts (CBCs), flow cytometry, blood grouping and antibody screens. Samples were also taken in 3.2% citrate tubes for coagulation test analyses. Results: Statistical differences were noted in all CBC parameters apart from the mean cell volume, eosinophil and basophil counts. Platelet counts were significantly different with an apparent rise after the addition of Triton X-100. Samples were noted to have a high red cell fragmentation index. Immunological platelet counting methods using flow cytometry and fluorescent methods showed no significant differences and gave reliable results. Neither flow cytometry for T-cell subsets nor blood grouping/antibody screens were affected by Triton X-100. However, coagulation samples were severely haemolysed prohibiting analysis. Conclusions: We have demonstrated that the addition of Triton X-100 to haematology blood samples impacts mainly on platelet counts and coagulation studies due to haemolysis. The platelet count is spuriously raised probably due to the presence of red cell fragments. The latter can be circumvented by the use of immunological platelet counting technology.en_GB
dc.language.isoenen_GB
dc.publisherBMJ Groupen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectOctoxynolen_GB
dc.subjectEbola virus disease -- Treatmenten_GB
dc.subjectBlood -- Diseases -- Diagnosisen_GB
dc.subjectBlood coagulation testsen_GB
dc.subjectHemolysis and hemolysinsen_GB
dc.titleA feasibility study on the effects of Triton X-100 for the in vitro inactivation of Ebola virus on haematological assaysen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1136/jclinpath-2015-203331-
dc.publication.titleJournal of Clinical Pathologyen_GB