Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/103578
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGatt, Alfred-
dc.contributor.authorChockalingam, Nachiappan-
dc.contributor.authorChatzistergos, Panagiotis-
dc.contributor.authorGatt, Ruben-
dc.contributor.authorSchembri-Wismayer, Pierre-
dc.contributor.authorGrima, Joseph N.-
dc.contributor.authorFormosa, Cynthia-
dc.date.accessioned2022-11-10T16:21:23Z-
dc.date.available2022-11-10T16:21:23Z-
dc.date.issued2021-
dc.identifier.citationGatt, A., Chockalingam, N., Chatzistergos, P., Gatt, R., Schembri-Wismayer, P., Grima, J. N., & Formosa, C. (2021). The biomechanical properties of human fresh-frozen vs thiel embalmed foot tendons. Acta Scientific Orthopaedics, 4(11), 19-23.en_GB
dc.identifier.issn25818635-
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/103578-
dc.description.abstractBackground: The aim of this study was to directly compare the effects of Thiel embalming on the mechanical properties of three human tendons to similar tendons from the fresh-frozen, ipsilateral foot of the same cadavers. Method: Following pre-conditioning, biomechanical tensile tests were conducted on tibialis anterior, peroneus longus and Achilles tendons at a strain rate of 5 mm/minute, using an optical extensometer for the direct measurement of sample strain. Results: Qualitatively, all tested tendons exhibited similar mechanical behaviour characterised by an initial toe region followed by a region of linear behaviour. Quantitatively, however, averaging the results for the three cadaveric samples revealed consistent differences across all tendons in the case of unloading stiffness. Conclusion: Thiel embalming method is suitable for preservation of human tendons, with embalmed tendons appearing to have similar mechanical behaviour compared to their fresh frozen counterparts. Although quantitative differences do exist, these do not disprove the use of Thiel embalmed tendons in comparative studies once care is exercised when utilizing these for biomechanical testing. However, in vitro results used to infer in vivo function should always be treated with caution.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectTendonsen_GB
dc.subjectBiomechanicsen_GB
dc.subjectAnatomyen_GB
dc.titleThe biomechanical properties of human fresh-frozen vs thiel embalmed foot tendonsen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.publication.titleActa Scientific Orthopaedicsen_GB
Appears in Collections:Scholarly Works - FacHScPod

Files in This Item:
File Description SizeFormat 
The_biomechanical_properties_of_human_fresh_frozen_vs_thiel_embalmed_foot_tendons_2021.pdf463.82 kBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.