Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/104257
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gatt, Alfred | - |
dc.contributor.author | Gatt, Ruben | - |
dc.contributor.author | Schembri Wismayer, Pierre | - |
dc.contributor.author | Grima, Joseph N. | - |
dc.contributor.author | Chatzistergos, Panagiotis | - |
dc.contributor.author | Chockalingam, Nachiappan | - |
dc.contributor.author | Formosa, Cynthia | - |
dc.date.accessioned | 2022-12-09T07:58:32Z | - |
dc.date.available | 2022-12-09T07:58:32Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Gatt, A., Gatt, R., Schembri Wismayer, P., Grima, J. N., Chatzistergos, P., Chockalingam, N., & Formosa, C. (2016). Investigating the mechanical properties of Thiel-embalmed metatarsals. Journal of Medical Biomedical and Applied Sciences, 4(12), 34-36. | en_GB |
dc.identifier.issn | 2349-0748 | - |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/104257 | - |
dc.description.abstract | Introduction: Fresh-frozen cadaveric samples are often utilized for research and the study of anatomy. Thiel embalming offers the possibility of preserving human tissue and bone without requiring special freezing equipment. Thus mechanically testing Thiel embalmed bone to compare with fresh frozen samples becomes increasingly important. Method: The 1st and 5th metatarsals were harvested from 3 cadavers which had one foot fresh frozen and the other Thiel embalmed. These metatarsals underwent 3-point testing until fracture. Results: 5th metatarsal average fracture force for Thiel embalmed and fresh frozen samples was equal to 305N (SD241N) and 539N (SD232N) respectively. Similarly average fracture force for Thiel embalmed and fresh frozen 1st metatarsals was equal to 614N (SD192N) and 694 (SD273N) respectively. Conclusion: Thiel embalmed metatarsals yield at a lower force than freshfrozen metatarsals obtained from the same cadaver. Thus one should be cautious about utilizing these preserved bones in situations where bone strength is required | en_GB |
dc.language.iso | en | en_GB |
dc.rights | info:eu-repo/semantics/openAccess | en_GB |
dc.subject | Metatarsal bones | en_GB |
dc.subject | Anatomy | en_GB |
dc.subject | Metatarsus | en_GB |
dc.title | Investigating the mechanical properties of Thiel-embalmed metatarsals | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.publication.title | Journal of Medical Biomedical and Applied Sciences | en_GB |
Appears in Collections: | Scholarly Works - FacHScPod |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Investigating_the_mechanical_properties_of_Thiel_embalmed_metatarsals_2016.pdf | 630.19 kB | Adobe PDF | View/Open |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.