Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/112355
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMercieca, Susan-
dc.contributor.authorBelderbos, Jose S. A.-
dc.contributor.authorvan Baardwijk, Angela-
dc.contributor.authorDelorme, Stefan-
dc.contributor.authorvan Herk, Marcel-
dc.date.accessioned2023-08-17T08:26:21Z-
dc.date.available2023-08-17T08:26:21Z-
dc.date.issued2019-
dc.identifier.citationMercieca, S., Belderbos, J. S., van Baardwijk, A., Delorme, S., & van Herk, M. (2019). The impact of training and professional collaboration on the interobserver variation of lung cancer delineations: a multi-institutional study. Acta Oncologica, 58(2), 200-208.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/112355-
dc.description.abstractBackground: To assess the impact of training and interprofessional collaboration on the interobserver variation in the delineation of the lung gross tumor volume (GTVp) and lymph node (GTVln).en_GB
dc.description.abstractMaterial and methods: Eight target volume delineations courses were organized between 2008 and 2013. Specialists and trainees in radiation oncology were asked to delineate the GTVp and GTVln on four representative CT images of a patient diagnosed with lung cancer individually prior each course (baseline), together as group (interprofessional collaboration) and post-training. The mean delineated volume and local standard deviation (local SD) between the contours for each course group were calculated and compared with the expert delineations.en_GB
dc.description.abstractResults: A total 410 delineations were evaluated. The average local SD was lowest for the interprofessional collaboration (GTVp ¼ 0.194 cm, GTVln¼ 0.371 cm) followed by the post-training (GTVp ¼ 0.244 cm, GTVln ¼ 0.607 cm) and baseline delineations (GTVp ¼ 0.274 cm, GTVln: 0.718 cm). The mean delineated volume was smallest for the interprofessional (GTVp¼ 4.93 cm3 , GTVln¼ 4.34 cm3 ) followed by the post-training (GTVp ¼ 5.68 cm3 , GTVln¼ 5.47 cm3 ) and baseline delineations (GTVp ¼ 6.65 cm3 , GTVln¼ 6.93 cm3 ). All delineations were larger than the expert for both GTVp and GTVln (p < .001).en_GB
dc.description.abstractConclusion: Our findings indicate that image interpretational differences can lead to large interob-server variation particularly when delineating the GTVln. Interprofessional collaboration was found to have the greatest impact on reducing interobserver variation in the delineation of the GTVln. This highlights the need to develop a clinical workflow so as to ensure that difficult cases are reviewed routinely by a second radiation oncologist or radiologist so as to minimize the risk of geographical tumor miss and unnecessary irradiation to normal tissue.en_GB
dc.language.isoenen_GB
dc.publisherTaylor & Francisen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectTumorsen_GB
dc.subjectLungs -- Canceren_GB
dc.subjectOncologyen_GB
dc.subjectRadiography, Medicalen_GB
dc.titleThe impact of training and professional collaboration on the interobserver variation of lung cancer delineations : a multi-institutional studyen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1080/0284186X.2018.1529422-
dc.publication.titleActa Oncologicaen_GB
Appears in Collections:Scholarly Works - FacHScRad



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.