Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/117689
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zammit, David | - |
dc.contributor.author | Baylon, Vincenzo | - |
dc.date.accessioned | 2024-01-19T14:41:44Z | - |
dc.date.available | 2024-01-19T14:41:44Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | Zammit, D., & Baylon, V. (2023). Biosensors for monitoring of vital functional parameters during medical emergency. Xjenza, 11(1-2), 3-9. | en_GB |
dc.identifier.issn | 18187269 | - |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/117689 | - |
dc.description.abstract | The objective of this work concerns the study of biosensors for monitoring of parameters and diagnosis of vital functional during first medical emergency. The study and analysis of vital parameters is extremely important in emergency medicine. The principle is based on the combination of the signals coming from the patient (vital functions), consists of measurement and comparison of the phase of active and reactive components of biologically active points (BAP) the transduction of such acquired signals and the processing of the obtained information. One of the advantages of reflex diagnostic methods is the fact that the response of BAPs to the change in the internal structure of the human body. These signals are proving instantaneous information on the functional state of 20 basic organ and system of the human body. The method will use one input variables (the classic physiological parameters and/or signals detected by using additive sensors) and one output variable which is correlated with the clinical condition of the patient. High information volume, accuracy, reliability, and reproducibility of data are supported in parallel in emergency diagnostics. A model will produce an association between the input variables and the output variable by using a data set established with the medical team. The proposed methodology improves standard systems such as reflex diagnostics, track and trigger and threshold (Early Warning Score). It is shown that good results for the prediction and early diagnosis in first medical emergency, through the adoption of the Fuzzy Set Theory. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Malta Chamber of Scientists | en_GB |
dc.rights | info:eu-repo/semantics/openAccess | en_GB |
dc.subject | Biosensors | en_GB |
dc.subject | Fuzzy logic | en_GB |
dc.subject | Vital signs -- Measurement -- Data processing | en_GB |
dc.subject | Medicine -- Research -- Data processing | en_GB |
dc.subject | Emergency medicine | en_GB |
dc.subject | Signal processing | en_GB |
dc.title | Biosensors for monitoring of vital functional parameters during medical emergency | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.7423/XJENZA.2023.2.01 | - |
dc.publication.title | Xjenza | en_GB |
Appears in Collections: | Xjenza, 2023, Volume 11, Issue 1 Xjenza, 2023, Volume 11, Issue 1 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Biosensors_for_monitoring_of_vital_functional_parameters_during_medical_emergency(2023).pdf | 1.2 MB | Adobe PDF | View/Open |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.