Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/118885
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDenby, Christine-
dc.contributor.authorChatterjee, Krishnendu-
dc.contributor.authorPullicino, Richard-
dc.contributor.authorLane, Steven-
dc.contributor.authorRadon, Mark-
dc.contributor.authorDas, Kumar V.-
dc.date.accessioned2024-02-20T09:40:24Z-
dc.date.available2024-02-20T09:40:24Z-
dc.date.issued2020-
dc.identifier.citationDenby, C. E., Chatterjee, K., Pullicino, R., Lane, S., Radon, M. R., & Das, K. V. (2020). Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review. Neuroradiology, 62, 273-281.en_GB
dc.identifier.issn14321920-
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/118885-
dc.description.abstractTo determine whether the sensitivity and specificity of four-dimensional CTA (4D-CTA) are equivalent to digital subtraction angiography (DSA) in the detection of underlying vascular abnormalities in patients with intracerebral haemorrhage (ICH). Methods A systematic review of studies comparing 4D-CTA with DSA in the detection of the underlying structural causes of ICH was performed on the literature published between 1998 and 2019. Results We identified a total of 237 articles from PubMed, SCOPUS and Web of Science using the following Medical Subject Headings (MeSH) terms: primary intracerebral haemorrhage, 4D-CTA, DSA, cerebral haemorrhage, angiography, digital subtraction, arteriovenous malformations, 4D, CTA, dynamic-CTA and time-resolved CTA. Following the removal of duplicate publications and articles failing to meet our inclusion criteria, there were four articles potentially viable for analysis. Therefore, there were not sufficient studies to provide a statistically meaningful meta-analysis. Conclusion The review of current literature has demonstrated that there are few published studies comparing 4D-CTA with DSA in spontaneous ICH, with only four suitable studies identified for potential analysis. However, due to the restricted number of patients and high sensitivity and specificity of 3 studies (100%), performing a meta-analysis was not meaningful. Qualitative analysis of the data concluded that 4D-CTA has the diagnostic potential to replace invasive DSA in certain cases with vascular abnormalities. However, further research studies directly comparing 4D-CTA with DSA using larger prospective patient cohorts are required to strengthen the evidence base.en_GB
dc.language.isoenen_GB
dc.publisherSpringeren_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectDigital subtraction angiographyen_GB
dc.subjectCerebrovascular diseaseen_GB
dc.subjectIntracerebral haemorrhageen_GB
dc.subjectCardiovascular system -- Abnormalitiesen_GB
dc.subjectSystematic reviews (Medical research)en_GB
dc.titleIs four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage : a systematic reviewen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1007/s00234-019-02349-z-
dc.publication.titleNeuroradiologyen_GB
Appears in Collections:Scholarly Works - FacM&SCRNM



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.