Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/119617
Full metadata record
DC FieldValueLanguage
dc.date.accessioned2024-03-11T07:24:15Z-
dc.date.available2024-03-11T07:24:15Z-
dc.date.issued2023-
dc.identifier.citationCiantar, K. (2023). The effect of precompression to masonry structures when subject to concentrated loads (Master's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/119617-
dc.descriptionM.Eng.(Melit.)en_GB
dc.description.abstractUnreinforced masonry (URM) has been the most predominant building type in the Maltese islands for a long period of time. The application of a concentrated load onto masonry walls is a very frequent case, and the ability to withstand a contact stress which is in excess of the wall’s uniaxial compressive strength has been known and studied for quite a long time. Existing knowledge, however, lacks when it comes to factor into the effect of precompression to masonry structures in relation to the strength enhancement phenomenon when subject to concentrated loads. An experimental programme was conducted to study this effect by representing masonry walls with scaled down homogenous concrete wall panels. This programme was split into 2 sets, implementing different loaded area ratios and design mixes. For each set, the precompressive stresses were varied in increments as a proportion of the previously found uniaxial compressive strength, and subsequently a central concentrated load was applied until failure. Results indicate that contrary to the original hypothesis, for the smaller precompressive stress ratios, the strength enhancement effect is even more amplified, which seemed to peak and decline back at higher ratios. No representative data was tested and collected for the higher precompressive stresses; however, one can hypothesise that the enhancement effect neutralises when the precompression approaches the uniaxial compressive bearing strength. Existing provisions given by masonry codes were also analysed and compared, highlighting possible future amendments to harmonise these codes by providing a holistic design equation including a modification factor to cater for the precompressive stresses.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectMasonry -- Maltaen_GB
dc.subjectWalls -- Maltaen_GB
dc.subjectLoads (Mechanics)en_GB
dc.titleThe effect of precompression to masonry structures when subject to concentrated loadsen_GB
dc.typemasterThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty for the Built Environment. Department of Civil and Structural Engineeringen_GB
dc.description.reviewedN/Aen_GB
dc.contributor.creatorCiantar, Kurt (2023)-
Appears in Collections:Dissertations - FacBen - 2023
Dissertations - FacBenCSE - 2023

Files in This Item:
File Description SizeFormat 
2318BENCVE502000010622_1.PDF15.83 MBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.