Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/119630
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.date.accessioned | 2024-03-11T07:55:27Z | - |
dc.date.available | 2024-03-11T07:55:27Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | Seisun, S. (2023). Corrosion of reinforcement in concrete: electrochemical chloride extraction (Master's dissertation). | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/119630 | - |
dc.description | M.Eng.(Melit.) | en_GB |
dc.description.abstract | In recent decades, some reinforced concrete buildings have come to be regarded as culturally significant due to their architectural or social importance. Such structures include buildings, infrastructure, and disused industrial facilities. Unfortunately, many of these sites are vulnerable to damage from the effects of concrete carbonation and corrosion of embedded steel bars, particularly in coastal structures. To address this issue, a study was undertaken on the Fire Control Tower (1938) in Fort St. Elmo in Valletta, Malta. The project's objective was to assess the applicability and performance of Electrochemical Chloride Extraction (ECE) on historic reinforced concrete structures exposed to a marine environment (air-borne salts). A comprehensive appraisal was conducted to investigate the degradation processes and ascertain the cause of the deterioration. The assessment included a visual inspection supplemented with photogrammetry and non-destructive testing (NDT). Various NDT techniques were employed, including Cover Metre, Ultrasonic Pulse Echo, Resistivity, Schmidt Hammer, Thermal Camera, Ground Penetrating Radar (GPR) and Half-Cell Potential. The research involved examining two locations, one facing the sea and one facing the land, to ascertain chloride's presence and predict its accumulation on concrete surfaces and within its structure under different exposure conditions. An electrochemical chloride extraction system was implemented for 24 days as a temporary solution, using synthesized pore solutions as electrolytes and with an applied current density of 1A/m2 . Additionally, cores were extracted to assess the efficiency of the treatment in removing harmful chlorides from the structure, with a comparison between cores from treated and untreated areas. Material testing was conducted to assess if the ECE had any effects on the electrochemical properties of the materials. Materials analysis conducted on extracted cores included; carbonation, density, vacuum saturation porosity, and compressive strength. The study results indicate that ECE treatment was successfully applied to the historic concrete structure, and no further damage was done to the structure and can be considered a viable and practical approach to mitigating the damage caused by chloride accumulation on concrete surfaces. | en_GB |
dc.language.iso | en | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Historic buildings -- Malta | en_GB |
dc.subject | Weathering of buildings -- Malta | en_GB |
dc.subject | Reinforced concrete -- Corrosion -- Malta | en_GB |
dc.subject | Reinforced concrete -- Electrochemical chloride extraction -- Malta | en_GB |
dc.title | Corrosion of reinforcement in concrete : electrochemical chloride extraction | en_GB |
dc.type | masterThesis | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.publisher.institution | University of Malta | en_GB |
dc.publisher.department | Faculty for the Built Environment. Department of Civil and Structural Engineering | en_GB |
dc.description.reviewed | N/A | en_GB |
dc.contributor.creator | Seisun, Sharona (2023) | - |
Appears in Collections: | Dissertations - FacBen - 2023 Dissertations - FacBenCSE - 2023 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2318BENCVE502000010920_1.PDF Restricted Access | 20.78 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.