Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/125754
Title: | Handles with reentrant cells for use as oar handles : design considerations, physical characteristics, and end-users’ perceptions |
Authors: | Grima-Cornish, James N. Attard, Daphne Gatt, Alfred Ficarra, Giovanni Cerasola, Dario Saliba Thorne, Claire Albanozzo, Andrew Albanozzo, Paul Gatt, Ruben Formosa, Cynthia Grima, Joseph N. |
Keywords: | Rowing -- Equipment and supplies Handles -- Design and construction Sports equipment -- Design and construction Auxetics (Materials) -- Mechanical properties Hand strength -- Physiology |
Issue Date: | 2024 |
Publisher: | Wiley-VCH Verlag GmbH & Co. KGaA |
Citation: | Grima‐Cornish, J. N., Attard, D., Gatt, A., Ficarra, G., Cerasola, D., Saliba Thorne, C.,...Grima, J. N. (2024). Handles with Reentrant Cells for Use as Oar Handles: Design Considerations, Physical Characteristics, and End‐Users’ Perceptions. Physica Status Solidi. B, 2400300. |
Abstract: | Rowing is a sport that requires athletes to perform the action of pulling and rotating an oar by hand, applying forces of considerable magnitude. Herein, inspired by the notion that auxetic materials and metamaterials behave differently compared to their conventional counterparts, it is examined how a handle prototype, specifically designed to incorporate the classic re-entrant motif, behaves and how end-users perceive it. Physical experiments conducted on such prototype, which measured the contact pressures, suggest that on average, higher pressures are measured when pulling with this reentrant grip compared to its non reentrant counterpart, indicating that this re-entrant prototype should feel firmer. More importantly, respondents of a survey are asked to give their feedback, and different views on which handle they would prefer to use are provided. The ones who preferred the prototype with the reentrant features report that they preferred it because it felt firmer and allowed for a better grip. This suggests that there is potential for further investigation into whether handles, oar handles in particular, made from auxetic components, re-entrant cells, or other motifs which are well known for their negative Poisson’s ratio characteristics, could provide a better and more secure grip and be used in sports applications. |
URI: | https://www.um.edu.mt/library/oar/handle/123456789/125754 |
Appears in Collections: | Scholarly Works - FacHScPod |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Handles with reentrant cells for use as oar handles design considerations physical characteristics and end users perceptions 2024.pdf Restricted Access | 1.13 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.