Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/18687
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCasha, Aaron-
dc.contributor.authorGatt, Ruben-
dc.contributor.authorDuca, Edward-
dc.contributor.authorGauci, Marilyn-
dc.contributor.authorSchembri-Wismayer, Pierre-
dc.contributor.authorCamilleri-Podesta, Marie Therese-
dc.contributor.authorGrima, Joseph N.-
dc.contributor.authorManche, Alexander-
dc.date.accessioned2017-04-27T11:59:47Z-
dc.date.available2017-04-27T11:59:47Z-
dc.date.issued2014-
dc.identifier.citationCasha, A., Gatt, R., Duca, E., Gauci, M., Schembri Wismayer, P., Camilleri-Podesta, M. T., ... Manche, A. (2014). Mechanism of sternotomy dehiscence. Interactive CardioVascular and Thoracic Surgery, 19(4), 617-621.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/18687-
dc.descriptionResearch funded by the University of Malta.en_GB
dc.description.abstractOBJECTIVES Biomechanical modelling of the forces acting on a median sternotomy can explain the mechanism of sternotomy dehiscence, leading to improved closure techniques. METHODS Chest wall forces on 40 kPa coughing were measured using a novel finite element analysis (FEA) ellipsoid chest model, based on average measurements of eight adult male thoracic computerized tomography (CT) scans, with Pearson's correlation coefficient used to assess the anatomical accuracy. Another FEA model was constructed representing the barrel chest of chronic obstructive pulmonary disease (COPD) patients. Six, seven and eight trans-sternal and figure-of-eight closures were tested against both FEA models. RESULTS Comparison between chest wall measurements from CT data and the normal ellipsoid FEA model showed an accurate fit (P < 0.001, correlation coefficients: coronal r = 0.998, sagittal r = 0.991). Coughing caused rotational moments of 92 Nm, pivoting at the suprasternal notch for the normal FEA model, rising to 118 Nm in the COPD model (t-test, P < 0.001). The threshold for dehiscence was 84 Nm with a six-sternal-wire closure, 107 Nm with seven wires, 127 Nm with eight wires and 71 Nm for three figure-of-eights. CONCLUSIONS The normal rib cage closely fits the ellipsoid FEA model. Lateral chest wall forces were significantly higher in the barrel-shaped chest. Rotational moments generated by forces acting on a six-sternal-wire closure at the suprasternal notch were sufficient to cause lateral distraction pivoting at the top of the manubrium. The six-sternal-wire closure may be successfully enhanced by the addition of one or two extra wires at the lower end of the sternotomy, depending on chest wall shape.en_GB
dc.language.isoenen_GB
dc.publisherOxford University Pressen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectSternum -- Surgeryen_GB
dc.subjectBiomechanicsen_GB
dc.subjectBiological modelsen_GB
dc.subjectSurgery -- Complicationsen_GB
dc.titleMechanism of sternotomy dehiscenceen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1093/icvts/ivu184-
Appears in Collections:Scholarly Works - CenEBI
Scholarly Works - FacEduMSE
Scholarly Works - FacM&SAna
Scholarly Works - FacSciChe
Scholarly Works - FacSciMet

Files in This Item:
File Description SizeFormat 
OA - Mechanism of sternotomy dehiscence.1.pdfMechanism of sternotomy dehiscence503.98 kBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.