Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/20499
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDuque, Jussaro Alves-
dc.contributor.authorFernandes, Samuel Lucas-
dc.contributor.authorBubola, J. P.-
dc.contributor.authorDuarte, Marco Antonio Hungaro-
dc.contributor.authorCamilleri, Josette-
dc.contributor.authorMarciano, Marina Angelica-
dc.date.accessioned2017-07-19T07:41:33Z-
dc.date.available2017-07-19T07:41:33Z-
dc.date.issued2017-
dc.identifier.citationDuque, J. A., Fernandes, S. L., Bubola, J. P., Duarte, M. A. H., Camilleri, J., & Marciano, M. A. (2017). The effect of mixing method on tricalcium silicate‐based cement. International Endodontic Journal.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/20499-
dc.description.abstractAim: To evaluate the effect of three methods of mixing on the physical and chemical properties of tricalcium silicate-based cements. Methodology: The materials evaluated were MTA Angelus and Portland cement with 20% zirconium oxide (PC-20-Zr). The cements were mixed using a 3: 1 powder-to-liquid ratio. The mixing methods were manual (m), trituration (tr) and ultrasonic (us) activation. The materials were characterized by means of scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy. Flowability was analysed according to ANSI/ADA 57/2012. Initial and final setting times were assessed following ASTM C266/08. Volume change was evaluated using a micro-CT volumetric method. Solubility was analysed according to ADA 57/2012. pH and calcium ion release were measured after 3, 24, 72 and 168 h. Statistical analysis was performed using two-way analysis of variance. The level of significance was set at P = 0.05. Results: The SEM analysis revealed that ultrasonic activation was associated with a homogeneous distribution of particles. Flowability, volume change and initial setting time were not influenced by the mixing method (P > 0.05). Solubility was influenced by the mixing method (P < 0.05). For pH, at 168 h, significant differences were found between MTA-m and PC-20-Zr-m (P < 0.05). For calcium ion release, PC-20-Zr-tr had higher values than MTA-m at 3 h, and MTA-tr had higher values than PC-20-Zr-m at 168 h (P < 0.05). Conclusions: The ultrasonic and trituration methods led to higher calcium ion release and pH compared with manual mixing for all cements, whilst the ultrasonic method produced smaller particles for the PC-20-Zr cement. Flow, setting times and volume change were not influenced by the mixing method used; however, it did have an impact on solubility.en_GB
dc.language.isoenen_GB
dc.publisherBlackwell Publishing Ltd.en_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectEndodonticsen_GB
dc.subjectDental materialsen_GB
dc.titleThe effect of mixing method on tricalcium silicate-based cementen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1111/iej.12774-
dc.publication.titleInternational Endodontic Journalen_GB
Appears in Collections:Scholarly Works - FacDenRS

Files in This Item:
File Description SizeFormat 
Duque_et_al-2017-International_Endodontic_Journal.pdf
  Restricted Access
580.57 kBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.