dc.contributor.authorSalvachua, Belen-
dc.contributor.authorBruce, Roderik-
dc.contributor.authorCarra, Federico-
dc.contributor.authorDemicoli, Marija-
dc.contributor.authorHofle, Wolfgang-
dc.contributor.authorHolzer, Eva Barbara-
dc.contributor.authorJacquet, D.-
dc.contributor.authorMirarchi, Daniele-
dc.contributor.authorBusto, E. Nebot del-
dc.contributor.authorRedaelli, Stefano-
dc.contributor.authorRossi, Adriana-
dc.contributor.authorSapinski, M.-
dc.contributor.authorSchmidt, Ruediger-
dc.contributor.authorValentino, Gianluca-
dc.contributor.authorValuch, Daniel-
dc.contributor.authorWenninger, Jorg-
dc.contributor.authorWollmann, Daniel-
dc.contributor.authorZerlauth, Markus-
dc.contributor.authorLari, Luisella-
dc.date.accessioned2018-04-06T07:04:01Z-
dc.date.available2018-04-06T07:04:01Z-
dc.date.issued2014-
dc.identifier.citationSalvachua, B., Holzer, E., Mirarchi, D., Valentino, G., Valuch, D., Wollmann, D., ... & Sapinski, M. (2014). Handling 1 MW losses with the LHC collimation system. 5th International Particle Accelerator Conference, Dresden. 174-177.en_GB
dc.identifier.isbn9783954501328-
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/28816-
dc.description.abstractThe LHC superconducting magnets in the dispersion suppressor of IR7 are the most exposed to beam losses leaking from the betatron collimation system and represent the main limitation for the halo cleaning. In 2013, quench tests were performed at 4 TeV to improve the quench limit estimates, which determine the maximum allowed beam loss rate for a given collimation cleaning. The main goal of the collimation quench test was to try to quench the magnets by increasing losses at the collimators. Losses of up to 1 MW over a few seconds were generated by blowing up the beam, achieving total losses of about 5.8 MJ. These controlled losses exceeded by a factor 2 the collimation design value, and the magnets did not quench.en_GB
dc.language.isoenen_GB
dc.publisherJACoWen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectLarge Hadron Collider (France and Switzerland)en_GB
dc.subjectCollimators (Optical instrument) -- Calibrationen_GB
dc.subjectColliders (Nuclear physics)en_GB
dc.titleHandling 1 MW losses with the LHC collimation systemen_GB
dc.typeconferenceObjecten_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.bibliographicCitation.conferencename5th International Particle Accelerator Conferenceen_GB
dc.bibliographicCitation.conferenceplaceDresden, Germany, 15-20/06/2014en_GB
dc.description.reviewedpeer-revieweden_GB
Appears in Collections:Scholarly Works - FacICTCCE
Scholarly Works - InsSE

Files in This Item:
File Description SizeFormat 
Handling_1_MW_losses_with_the_LHC_collimation_system.pdf828.24 kBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.