dc.identifier.citationGatt, R. (2011). An analysis of dose related data from pacemaker implant procedures (Bachelor's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/52994-
dc.descriptionB.SC.(HONS)RADIOGRAPHYen_GB
dc.description.abstractObjectives: The objectives of the project were to record the values of CKAP and CAK1RP and fluoroscopic time during pacemaker implants of adult patients at a general hospital cardiac catetherization suite in Malta, compare the mean values with corresponding values in the international literature, observe how these values vary with patient size, pacemaker and suggest room Diagnostic Reference Levels. Research Design: For 17 procedures concerning three different types of pacemakers (single, dual and temporary), the CKAP, CAK1RP and fluoroscopy times were recorded. The level of correlation of CKAP and the CAK1RP and fluoroscopy time with patient size parameters were investigated using standard statistical methods. Results: The main results of the project were: • The average values of CAK1RP and CKAP were 0.0897Gy and 7.28Gycm2 respectively, for the category of standard sized patients that underwent a dual pacemaker implantation. These values were generally lower than those found in the literature. • The average values for CAK and C KAPrRP for standard patients were set as room DRL s. However, in view of the low patient sample size these values should be considered provisional. Conclusion: In view of the low patient sample size it is recommended that a more extended study be carried out.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectRadiography, Medical -- Maltaen_GB
dc.subjectCardiac catheterizationen_GB
dc.subjectCardiac pacingen_GB
dc.subjectFluoroscopyen_GB
dc.subjectCardiac pacemakersen_GB
dc.titleAn analysis of dose related data from pacemaker implant procedures.en_GB
dc.typebachelorThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Health Sciences. Department of Radiographyen_GB
dc.contributor.supervisorCaruana, Carmel J.-
dc.description.reviewedN/Aen_GB
dc.contributor.creatorGatt, Rochelle-
Appears in Collections:Dissertations - FacHSc - 2011
Dissertations - FacHScRad - 2011

Files in This Item:
File Description SizeFormat 
Gatt_Rochelle_An Analysis of dose related data.PDF
  Restricted Access
4.86 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.