dc.identifier.citation | Gatt, R. (2011). An analysis of dose related data from pacemaker implant procedures (Bachelor's dissertation). | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/52994 | - |
dc.description | B.SC.(HONS)RADIOGRAPHY | en_GB |
dc.description.abstract | Objectives: The objectives of the project were to record the values of CKAP and CAK1RP and fluoroscopic time during pacemaker implants of adult patients at a general hospital cardiac catetherization suite in Malta, compare the mean values with corresponding values in the international literature, observe how these values vary with patient size, pacemaker and suggest room Diagnostic Reference Levels. Research Design: For 17 procedures concerning three different types of pacemakers (single, dual and temporary), the CKAP, CAK1RP and fluoroscopy times were recorded. The level of correlation of CKAP and the CAK1RP and fluoroscopy time with patient size parameters were investigated using standard statistical methods. Results: The main results of the project were: • The average values of CAK1RP and CKAP were 0.0897Gy and 7.28Gycm2 respectively, for the category of standard sized patients that underwent a dual pacemaker implantation. These values were generally lower than those found in the literature. • The average values for CAK and C KAPrRP for standard patients were set as room DRL s. However, in view of the low patient sample size these values should be considered provisional. Conclusion: In view of the low patient sample size it is recommended that a more extended study be carried out. | en_GB |
dc.language.iso | en | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Radiography, Medical -- Malta | en_GB |
dc.subject | Cardiac catheterization | en_GB |
dc.subject | Cardiac pacing | en_GB |
dc.subject | Fluoroscopy | en_GB |
dc.subject | Cardiac pacemakers | en_GB |
dc.title | An analysis of dose related data from pacemaker implant procedures. | en_GB |
dc.type | bachelorThesis | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.publisher.institution | University of Malta | en_GB |
dc.publisher.department | Faculty of Health Sciences. Department of Radiography | en_GB |
dc.contributor.supervisor | Caruana, Carmel J. | - |
dc.description.reviewed | N/A | en_GB |
dc.contributor.creator | Gatt, Rochelle | - |
Appears in Collections: | Dissertations - FacHSc - 2011 Dissertations - FacHScRad - 2011 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Gatt_Rochelle_An Analysis of dose related data.PDF Restricted Access | 4.86 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.