Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/54122
Full metadata record
DC FieldValueLanguage
dc.date.accessioned2020-04-14T07:38:15Z-
dc.date.available2020-04-14T07:38:15Z-
dc.date.issued2006-
dc.identifier.citationCini, C. (2006). Maximizing bacterial isolation rates from CAPD fluid specimen (Bachelor's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/54122-
dc.descriptionB.SC.(HONS)MED.LAB.SCI.en_GB
dc.description.abstractThe major complication of Continuous Ambulatory Peritoneal Dialysis (CAPD) is Peritonitis which can be caused by various micro-organisms. The problem with CAPD fluid is that current culturing techniques lack sensitivity and result in a percentage of false negative cultures (10% to 50%). During this study, two culture techniques, which are the lysis-centrifugation by osmosis and Blood culture technique using BACTEC blood culture system, will be compared together and with the centrifugation technique, which is the current culturing technique for CAPD fluid at the Bacteriology laboratory at St. Luke's Hospital. A total of 53 samples were collected, 77% of which were positive cultures with all or any one method and 23% were negative cultures with all methods. From the total positive cultures (41}, 87.8% were recovered with the lysis-centrifugation technique, 90.2% with the centrifugation technique and 92.6% with the blood culture techniques. From the significance association test carried out, the Fisher's Exact Test, it was found that there was no significant difference between the positive culture outcome achieved with the three culturing methods (p = 0.756). The frequency of each organism isolated during the study was almost the same with every one method thus confirming that there was not significant difference between the methods. Therefore no method could be said to yield more positive results than another method used during this study.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectContinuous ambulatory peritoneal dialysisen_GB
dc.subjectPeritonitisen_GB
dc.subjectCentrifugationen_GB
dc.subjectBacteriologyen_GB
dc.titleMaximizing bacterial isolation rates from CAPD fluid specimen.en_GB
dc.typebachelorThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Health Sciences.en_GB
dc.contributor.supervisorSaid, Edith-
dc.description.reviewedN/Aen_GB
dc.contributor.creatorCini, Catriona-
Appears in Collections:Dissertations - FacHSc - 2006
Dissertations - FacHScABS - 2006

Files in This Item:
File Description SizeFormat 
Cini_Catriona.pdf
  Restricted Access
5.51 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.