Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/54187
Full metadata record
DC FieldValueLanguage
dc.date.accessioned2020-04-14T15:13:01Z-
dc.date.available2020-04-14T15:13:01Z-
dc.date.issued2006-
dc.identifier.citationZammit, M. (2006). The efficacy of donor arm disinfection techniques in reducing platelet contamination (Bachelor's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/54187-
dc.descriptionB.SC.(HONS)MED.LAB.SCI.en_GB
dc.description.abstractBacterial contamination of blood and its components can be mostly attributed to inadequate skin venipuncture site disinfection, defective blood bags and associated equipment together with inappropriate storage or processing. Since platelets are stored at room temperature (21-23°C), they are most likely to be contaminated since bacterial growth is enhanced at this temperature. The main aim of this study was to validate the current method used to disinfect the donor's arm using 70% Isopropyl Alcohol (IPA) carried out at the four different blood donation sites:- The National Blood Transfusion Centre (NBTC), Gozo General Hospital (GGH), Soverign Military Order of Malta (SMOM) and Mobile unit. This study found a statistically significant difference between bacterial counts present on the non-donation arm and those present on the donation arm following disinfection (p < 0.01). There was no statistically significant difference between gender and bacterial counts (p = 0.918). Negative correlation was present between bacterial counts and donor age (p = 0.874). Disinfection methods using 70% IPA, and 70% IPA followed by the application of decolorised Iodine Tincture were compared in relation to bacterial counts present on the donation arm following disinfection. Both disinfection methods yielded optimal results namely zero bacterial counts at the venipuncture site following disinfection. This study concludes that the skin disinfection technique currently in use at the four blood donation sites using 70% IPA is effective enough in reducing bacterial contamination of blood and its components.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectBlood plateletsen_GB
dc.subjectBlood -- Transfusionen_GB
dc.subjectDisinfection and disinfectantsen_GB
dc.subjectMicrobial contaminationen_GB
dc.subjectBlood donorsen_GB
dc.titleThe efficacy of donor arm disinfection techniques in reducing platelet contamination.en_GB
dc.typebachelorThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Health Sciences.en_GB
dc.contributor.supervisorAquilina, A.-
dc.description.reviewedN/Aen_GB
dc.contributor.creatorZammit, Martine-
Appears in Collections:Dissertations - FacHSc - 2006
Dissertations - FacHScABS - 2006

Files in This Item:
File Description SizeFormat 
Zammit_Martine.pdf
  Restricted Access
4.88 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.