dc.identifier.citationCini, M. (2019). Validation of methods for testing drugs of abuse (Master's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/58620-
dc.descriptionM.PHARM.en_GB
dc.description.abstractSeveral methods of drug testing, for cases of seized drugs, have been developed over the years. All methods need to be validated. This study validates methods for the identification and quantification (percentage purity) of illegal drugs using Gas Chromatography-Mass Spectrometry (GC-MS). The methods were developed, calibrated and validated, according to standards set by the United Nations Office on Drugs and Crime (UNODC). In the first phase, methods were developed specifically for cocaine, diacetylmorphine (DAM) and 3,4-methylenedioxymetamphetamine (3,4 MDMA) and in the second phase, a method was developed for cannabis. Diphenylamine was used as an internal standard. Validation results in phase 1 (testing for cocaine, DAM, and 3,4-MDMA) showed that: 1) the method was linear from the limit of detection (LOD) to the highest calibration point, with R2 values >0.99 [0.9982, 0.9961, 0.997] 2) the LOD was 1% 3) the limit of quantification (LOQ) was 1% for cocaine and 3,4-MDMA, and 12.5% for DAM 4) the method was successfully validated for accuracy and precision [% CV: -5.361, 2.445, 1.346 and % E: 9.257, 14.448, 13.550] 5) samples of cocaine and 3,4-MDMA were stable at room temperature for 36 hours and for 6 hours for DAM 6) no carry-over was observed between samples. The validation results in phase 2 (testing for levels of cannabidiol, cannabinol and delta 9-tetrahydrocannabinol [Δ9-THC] in cannabis) showed that: 1) the method was linear from the LOD to highest calibration point, with R2 values >0.99 [0.999,0.999,0.999] 2) the LOD was 0.01% and the LOQ was 0.1% 3) the method was validated for accuracy and precision at 2%, 10%, and 20% concentrations, as all the results fell under the recommended value of 15 4) samples were stable at room temperature for 24 hours 5) no carry-over was observed between samples. All validated parameters were within the limits set by the UNODC. The study was carried out at the forensic laboratory BioDNA at Life Sciences Park. The systems used were a Varian 450 GC-220 MS in phase 1 and an Agilent 6890 GC-5973 MSD in phase 2. Results were generated through Varian Inc. MS Workstation1 and Hewlett-Packard ChemStation2 respectively.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectDrug testingen_GB
dc.subjectGas chromatographyen_GB
dc.subjectMass spectrometryen_GB
dc.titleValidation of methods for testing drugs of abuseen_GB
dc.typemasterThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Medicine and Surgery. Department of Pharmacyen_GB
dc.description.reviewedN/Aen_GB
dc.contributor.creatorCini, Michaela-
Appears in Collections:Dissertations - FacM&S - 2019
Dissertations - FacM&SPha - 2019

Files in This Item:
File Description SizeFormat 
1111 Validation of Methods for Testing drugs of abuse.pdf
  Restricted Access
2.7 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.