Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/58811
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCassar, Johann-
dc.contributor.authorSammut, Andrew-
dc.contributor.authorSammut, Nicholas-
dc.contributor.authorCalvi, Marco-
dc.contributor.authorSpasic, Sasa-
dc.contributor.authorPopovic Renella, Dragana-
dc.date.accessioned2020-07-16T08:07:00Z-
dc.date.available2020-07-16T08:07:00Z-
dc.date.issued2019-
dc.identifier.citationCassar, J., Sammut, A., Sammut, N., Calvi, M., Spasic, S., & Popovic Renella, D. (2019). Performance analysis of a reduced form-factor high accuracy three-axis teslameter. Electronics, 8(11), 1230.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/58811-
dc.description.abstractIn the framework of the SwissFEL project at the Paul Scherrer Institute (PSI), a Hall probe bench is being developed for the high-precision magnetic characterization of the insertion devices for the ATHOS soft X-ray beamline. For this purpose, a novel three-axis teslameter has been developed, which will be placed between the undulator and its outer shell in a very limited volumetric space of 150 × 50 × 45 mm. Together with a SENIS® 3-axis Hall probe at the center of the cross sectional area of the undulator, the setup will traverse along the undulator length on a specifically designed rig with minimal vibrations. This teslameter has all the analog signal conditioning circuitry for the Hall probe and also has on board 24-bit digitization. The instrument also handles an interface to a linear absolute encoder. The old instrumentation used only had analog signal conditioning circuitry whilst digitization was done off board. The new instrument also provides a very accurate magnetic field map in the µT range with simultaneous readings from the position encoder at an accuracy of ±3 µm. In this paper, a series of tests are described, which were performed at PSI in order to establish the measuring precision and repeatability of the instrument.en_GB
dc.language.isoenen_GB
dc.publisherMDPI AGen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectWiggler magnetsen_GB
dc.subjectGrenz raysen_GB
dc.subjectAnalog-to-digital convertersen_GB
dc.subjectHall effecten_GB
dc.subjectMagnetismen_GB
dc.subjectMetal oxide semiconductors, Complementaryen_GB
dc.titlePerformance analysis of a reduced form-factor high accuracy three-axis teslameteren_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.3390/electronics8111230-
dc.publication.titleElectronicsen_GB
Appears in Collections:Scholarly Works - FacICTMN

Files in This Item:
File Description SizeFormat 
Performance_analysis_of_a_reduced_form_factor_high_accuracy_three_axis_teslameter.pdf5.63 MBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.