dc.contributor.authorDemicoli, Marija-
dc.contributor.authorMollicone, Pierluigi-
dc.contributor.authorMallia, Bertram-
dc.contributor.authorGrech, Ivan-
dc.contributor.authorPortelli, Barnaby-
dc.contributor.authorSammut, Nicholas-
dc.date.accessioned2020-07-23T07:43:06Z-
dc.date.available2020-07-23T07:43:06Z-
dc.date.issued2018-
dc.identifier.citationCauchi, M., Mollicone, P., Mallia, B., Grech, I., Portelli, B., & Sammut, N. (2018, May). Design and fabrication considerations, numerical modelling, and testing of a MEMS microgripper. In 2018 Symposium on Design, Test, Integration & Packaging of MEMS and MOEMS (DTIP) (pp. 1-6). IEEE.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/59000-
dc.description.abstractMicrogrippers play an important role in the manipulation of biological cells and tissues. This paper presents a horizontal electrothermally actuated microgripper that is designed for the handling and deformability characterization of human red blood cells (RBCs). Pathological alterations in the mechanical properties of RBCs have been associated with a number of specific diseases. This has accentuated the significance of analysing the deformability characteristics of RBCs within the biomedical field. A polysilicon microgripper structure was designed and fabricated according to the dimensional specifications imposed by the commercial PolyMUMPsTM fabrication process. The microgripper design was developed and numerically modelled using finite element analysis where coupled electrothermomechanical simulations were carried out in CoventorWare®. The fabrication method is presented in this paper, together with details of the experimental set-up used for the actuation testing. The tip displacement of the microgripper arm when electrothermally actuated is compared with that obtained by means of numerical simulations. Results show that the microgripper arm deflected as designed when electrothermally actuated, with good agreement obtained between simulation and experimental results. This paper also proposes critical design and fabrication considerations that were implied from the experimental campaign performed in this work and that take into account out-of-plane buckling of the hot arm, fracture of the arms in the vicinity of the anchored probe pads, residual stresses, and device stiction. Such considerations are regarded as an important outcome of this work, and they must be thoroughly investigated to mitigate the malfunction or failure of the microgripper.en_GB
dc.language.isoenen_GB
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectErythrocytesen_GB
dc.subjectResidual stressesen_GB
dc.subjectBiomechanicsen_GB
dc.subjectMolecular biologyen_GB
dc.subjectMicrurgyen_GB
dc.titleDesign and fabrication considerations, numerical modelling, and testing of a MEMS Microgripperen_GB
dc.typeconferenceObjecten_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.bibliographicCitation.conferencename20th Symposium on Design, Test, Integration and Packaging of MEMS and MOEMSen_GB
dc.bibliographicCitation.conferenceplaceRome, Italy, 22-25/05/2018en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1109/DTIP.2018.8394193-
Appears in Collections:Scholarly Works - FacEngMME
Scholarly Works - FacICTMN
Scholarly Works - InsSE