Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/82840
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBorg, Simon Paul-
dc.contributor.authorKelly, Nicolas James-
dc.date.accessioned2021-10-27T07:39:19Z-
dc.date.available2021-10-27T07:39:19Z-
dc.date.issued2012-
dc.identifier.citationBorg, S. P., & Kelly, N. J. (2012). The development and calibration of a generic dynamic absorption chiller model. Energy and Buildings, 55(12), 533-544.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/82840-
dc.description.abstractAlthough absorption cooling has been available for many years, the technology has typically been viewed as a poorly performing alternative to vapour compression refrigeration. However, rising energy prices and the requirement to improve energy-efficiency is driving renewed interest in the technology, particularly within the context of combined cooling, heat and power systems (CCHP) for buildings. In order to understand the performance of absorption cooling, numerous models are available in the literature. The complexities involved in the thermodynamics of absorption chillers have, however, so far restricted researchers to creating steady-state or dynamic models reliant on data measurements of the internal chiller state, which require difficult-to-obtain, intrusive measurements. The pragmatic, yet fully dynamic model described in this paper is designed to be easily calibrated using data obtained from the measurements of inflows and outflows to a chiller, without resorting to intrusive measurements. The model comprises a series of linked control volumes featuring both performance maps and lumped mass volumes, which reflect the underlying physical structure of the device. The paper describes the modelling approach, theory and limitations, along with an example of the implementation of the model in the ESP-r code complete with calibration and an application to a specific example.en_GB
dc.language.isoenen_GB
dc.publisherElsevier BVen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectAir conditioningen_GB
dc.subjectCoolingen_GB
dc.subjectBuildings -- Energy conservationen_GB
dc.subjectBuildings -- Environmental engineeringen_GB
dc.titleThe development and calibration of a generic dynamic absorption chiller modelen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1016/j.enbuild.2012.08.046-
dc.publication.titleEnergy and Buildingsen_GB
Appears in Collections:Scholarly Works - FacBenED

Files in This Item:
File Description SizeFormat 
The_development_and_calibration_of_a_generic_dynamic_absorption_chiller_model_2012.pdf
  Restricted Access
1.29 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.