Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/85904
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dogariu, Adrian | - |
dc.contributor.author | Dubina, Dan | - |
dc.contributor.author | Campitiello, F. | - |
dc.contributor.author | De Matteis, Gianfranco | - |
dc.date.accessioned | 2021-12-21T09:49:53Z | - |
dc.date.available | 2021-12-21T09:49:53Z | - |
dc.date.issued | 2008 | - |
dc.identifier.citation | Dogariu, A., Dubina, D., Campitiello, F., & De Matteis, G. (2008). FEM modeling masonry shear walls strengthened with metal sheathing. In Mazzolani, F. M., Mistakidis, E., Borg, R. P., Byfield, M., De Matteis, G., Dubina.,..Wang, Y. (Eds.), Urban habitat constructions under catastrophic events: COST Action C26 (pp. 235-240). Malta: University of Malta. Dept. of Building & Civil Engineering. | en_GB |
dc.identifier.isbn | 9789990944402 | - |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/85904 | - |
dc.description.abstract | ▪ Application of different finite element models to simulate the behaviour of masonry is summarized. A particularly modeling technique and ABAQUS code is applied to evaluate performance of masonry walls sheeted with metallic plates (see COST 26 – WG2 – Datasheets “Retrofitting techniques for masonry panel based on steel and/or aluminium sheathing”). The retrofitting solutions and all the numerical analysis are developed within the frame of PROHITECH INCO-CT-2004-509119. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | University of Malta. Department of Building & Civil Engineering | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Finite element method | en_GB |
dc.subject | Sheathing (Building materials) | en_GB |
dc.subject | Strength of materials -- Testing | en_GB |
dc.subject | Concrete walls -- Design and construction | en_GB |
dc.subject | Steel, Structural | en_GB |
dc.title | FEM modeling masonry shear walls strengthened with metal sheathing | en_GB |
dc.type | bookPart | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
Appears in Collections: | Urban habitat constructions under catastrophic events : COST Action C26 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
FEM_modeling_masonry_shear_walls_strengthened_with_metal_sheathing_2008.pdf Restricted Access | 741.46 kB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.