Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/92400
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shen, Xiaojun | - |
dc.contributor.author | Shukla, Pratik | - |
dc.contributor.author | Subramaniyan, Anand Kumar | - |
dc.contributor.author | Zammit, Ann | - |
dc.contributor.author | Swanson, Philip | - |
dc.contributor.author | Lawrence, Jonathan | - |
dc.contributor.author | Fitzpatrick, Michael E. | - |
dc.date.accessioned | 2022-03-25T09:59:43Z | - |
dc.date.available | 2022-03-25T09:59:43Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | Shen, X., Shukla, P., Subramaniyan, A. K., Zammit, A., Swanson, P., Lawrence, J., & Fitzpatrick, M. E. (2020). Residual stresses induced by laser shock peening in orthopaedic Ti-6Al-7Nb alloy. Optics & Laser Technology, 131, 106446. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/92400 | - |
dc.description.abstract | Prolonged usage can lead to fatigue failures in prosthetic implants. This is an emerging concern for the prosthesis designer and as well as for end-users. Laser shock peening (LSP) can be used to improve the life of prostheses by introducing a compressive surface stress that delays or arrests the initiation of cracks. We report measurements of residual stresses induced by LSP in a medical-grade Ti-6Al-7Nb alloy. In this paper, the LSP introduced residual stress field was characterized by using Incremental Hole Drilling (IHD) with predictive modelling using an Artificial Neural Network (ANN). The Ti-6Al-7Nb samples were processed by a pulsed Nd: YAG laser with laser energy of 3 J, 5 J and 7 J with overlaps of 33%, 50% and 67%. The IHD results show that a range of −42 MPa to −516 MPa compressive residual stresses are formed at the near surface. The residual stress value and affecting layer depth are proportional to laser energy and overlap. What is more, a gradient descent learning algorithm was employed in ANN prediction. The microhardness, laser energy, overlap and depth are set as input parameters while the residual stresses are output. The predicted results have a good agreement with the experimental data with accuracy of 96.16% and 95.16%. It proves that ANN is applicable in LSP residual stress simulation when the experimental data is limited. The work in this paper enables to have subsequent predictions of fatigue life of implants via residual stress fields for future applications. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Elsevier | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Implants, Artificial -- Surfaces | en_GB |
dc.subject | Surfaces (Technology) -- Analysis | en_GB |
dc.subject | Laser peening | en_GB |
dc.subject | Stress relieving (Materials) | en_GB |
dc.subject | Neural networks (Computer science) | en_GB |
dc.title | Residual stresses induced by laser shock peening in orthopaedic Ti-6Al-7Nb alloy | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.1016/j.optlastec.2020.106446 | - |
dc.publication.title | Optics & Laser Technology | en_GB |
Appears in Collections: | Scholarly Works - FacEngMME |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Residual_stresses_induced_by _laser_shock_peening_in_orthopaedic_Ti_6Al_7Nb_alloy_2020.pdf Restricted Access | 4.14 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.