Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/93405
Title: Improved visualization of renal lesions using three-dimensional ultrasound – a feasibility study
Authors: Helck, A.
D'Anastasi, Melvin
Notohamiprodjo, S.
Thieme, M.
Reiser, M.
Clevert, D. A.
Keywords: Kidneys -- Ultrasonic imaging
Three-dimensional imaging in medicine
Kidneys -- Cancer -- Diagnosis
Kidneys -- Tumors
Kidneys -- Diseases -- Diagnosis
Issue Date: 2011
Publisher: IOS Press
Citation: Helck, A., D'Anastasi, M., Notohamiprodjo, M., Thieme, S., Reiser, M., & Clevert, D. A. (2011). Improved visualization of renal lesions using three-dimensional ultrasound–a feasibility study. Clinical Hemorheology and Microcirculation, 49(1-4), 537-550.
Abstract: Purpose: To evaluate the potential benefit of three-dimensional ultrasound in the assessment of renal lesions. Materials and methods: 21 patients with unclear renal findings were prospectively included in the study. Every patient was examined using two-dimensional (2D) ultrasound (US), X-plane technique (simultaneous display of main image and second image at a plane at right angles to the first), and real time three-dimensional (3D) US. The imaging model used were standard gray scale-, duplex- and contrast-enhanced ultrasound (CEUS). All acquisitions were compared to each other with regard to image quality and identifiability of renal lesions. Additionally, when using the X-plane technique the quality of the first and the second image were analysed separately. The assessment was done using a subjective 6 point scale (1 = best). Results: All acquisitions were successfully performed and no patient had to be excluded. Image quality of real time 3D-US (score: 2.4±0.73) was slightly inferior to 2D-US and X-plane technique (main image) with a score of 2.2±0.43 and 2.2±0.5, respectively. The image quality of second image in the X-plane mode –due to a lower spatial resolution- was lower with a score of 3.2±0.5. Real time 3D-US and X-plane technique allowed for better identifiability (score: 1.4±0.59 and 1.9±0.53) of renal lesions compared to 2D-US (score: 2.5±0.6). The most marked difference was observed between the simultaneous use of real time 3D-US and X-plane technique versus 2D-US in case of renal cell carcinoma, especially with regard to extra-capsular tumor extension (score: 1.6±0.52, 1.8±0.71, and 3.0±0.52, respectively). Conclusion: Assessment of renal lesions using real time 3D-US is feasible and improves the identifiability of renal lesions.
URI: https://www.um.edu.mt/library/oar/handle/123456789/93405
Appears in Collections:Scholarly Works - FacM&SCRNM

Files in This Item:
File Description SizeFormat 
Improved_visualization_of_renal_lesions_using_three_dimensional_ultrasound_a_feasibility_study_2011.pdf
  Restricted Access
1.86 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.