Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/94527
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaid, Luke-
dc.contributor.authorRochman, Arif-
dc.contributor.authorFarrugia, Philip-
dc.contributor.authorVella, Pierre-
dc.date.accessioned2022-04-27T12:31:27Z-
dc.date.available2022-04-27T12:31:27Z-
dc.date.issued2014-08-
dc.identifier.citationSaid, L., Farrugia, P., Rochman, A., & Vella, P. (2014). Design of an endoscopic micro optical part for fabrication with micro two shot injection moulding. In International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, USA. 1-10.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/94527-
dc.description.abstractMicro two shot injection moulding (µtwo shot IM) is a manufacturing process capable of simultaneously replicating two polymeric parts and assembling them; removing the requirement for costly micro assembly. Endoscopes are used in medical environments to observe areas that are otherwise unobservable. µTwo shot IM has the potential to simultaneously replicate and assemble polymer lenses for endoscope imaging and assembling them to their required housing. In view of this, this paper contributes a case study part for application of µtwo shot injection moulding in the fabrication of an endoscopic micro optical component. This paper covers several aspects involved in the design of such a part. This novel design concept consists of an optical component and a housing component moulded sequentially on top of each other using µtwo shot IM. The lens component consisted of three lenses with a common base moulded as the first shot. The second shot moulded on onto the optical component was the housing component incorporating an external thread for interchangeability. From a material selection exercise it was concluded that cyclic olefin copolymer (COC) shall be used as the optical material and polyoxymethylene (POM) shall be used as the housing material. One major concern in the design of such a part is the deformation of the optical material by the housing material due to softening via heat transfer. Simulations of such a scenario were carried out and it was indicated that the functionality of the optical material shall not be compromiseden_GB
dc.language.isoenen_GB
dc.publisherASMEen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectMolding (Founding)en_GB
dc.subjectSustainability -- Case studiesen_GB
dc.subjectBuilding materialsen_GB
dc.subjectEnergy consumption -- Case studiesen_GB
dc.subjectOptical materialsen_GB
dc.titleDesign of an endoscopic micro optical part for fabrication with micro two shot injection mouldingen_GB
dc.typeconferenceObjecten_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.bibliographicCitation.conferencenameASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conferenceen_GB
dc.bibliographicCitation.conferenceplaceBuffalo, USA, 17-20/08/2014en_GB
dc.description.reviewedpeer-revieweden_GB
Appears in Collections:Scholarly Works - FacEngIME