Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/94529
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Borg, Kate | - |
dc.contributor.author | Rochman, Arif | - |
dc.date.accessioned | 2022-04-27T12:42:32Z | - |
dc.date.available | 2022-04-27T12:42:32Z | - |
dc.date.issued | 2013-09 | - |
dc.identifier.citation | Borg, A. K., & Rochman, A. (2013). Design, manufacture and testing of titanium EBM insert for injection molding. 6th International Conference on Advanced Research in Virtual and Rapid Prototyping, Portugal. 373-378. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/94529 | - |
dc.description.abstract | Rapid tooling technologies allow for quick fabrication of injection molding tools directly from Computer-Aided Design (CAD) data. In this study, the capability of producing tool inserts with freeform channels and the required finish and accuracy was examined. The investigation started with the design, manufacture and post-processing and ended with the testing of the tool inserts for injection molding process. Using the Electron Beam Melting (EBM) process, the restriction of drilling straight routes could be eliminated and freeform channels with sufficient powder removal were achieved. The choice of electron beam parameters and preheating sequence strongly influence the sintering levels of adjacent powder next to solidified tool inserts. Despite the very low heat conductivity of the new tool inserts made from titanium alloy Ti6Al4V Eli, the cooling performance was the same as for the conventional cavity inserts. However, titanium alloys have a high corrosion resistance that can prevent corrosion in injection molding process e.g. due to cooling medium or corrosive gas released by the polymer to be processed | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Taylor & Francis Group | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Molding (Founding) | en_GB |
dc.subject | Engineering design | en_GB |
dc.subject | Electron beams -- Industrial applications | en_GB |
dc.subject | Titanium alloys | en_GB |
dc.title | Design, manufacture and testing of titanium EBM insert for injection molding | en_GB |
dc.type | conferenceObject | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.bibliographicCitation.conferencename | International Conference on Advanced Research in Virtual and Rapid Prototyping | en_GB |
dc.bibliographicCitation.conferenceplace | Leiria, Portugal, 01-05/10/2013 | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
Appears in Collections: | Scholarly Works - FacEngIME |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Design_manufacture_and_testing_of_titanium_EBM_insert_for_injection_molding(2013).pdf Restricted Access | 1.86 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.