Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/95530
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWinter, K. S.-
dc.contributor.authorHolch, J.-
dc.contributor.authorHaindl, M.-
dc.contributor.authorSedlmair, M.-
dc.contributor.authorD'Anastasi, Melvin-
dc.contributor.authorJohnson, T.-
dc.contributor.authorTrumm, C. G.-
dc.contributor.authorSommer, W. H.-
dc.contributor.authorSchwarz, F.-
dc.date.accessioned2022-05-11T15:09:00Z-
dc.date.available2022-05-11T15:09:00Z-
dc.date.issued2016-03-
dc.identifier.citationWinter, K. S., Holch, J., Haindl, M., Sedlmair, M., D'Anastasi, M., Johnson, T.,...Schwarz, F. (2016). Increased reproducibility of semiautomatic 3D-segmentation over 2D-measurements for quantification of specific iodine uptake of hepatic colorectal metastases in dual-energy CT. European Congress of Radiology-ECR 2016, Vienna.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/95530-
dc.description.abstractWith its capability to quantify absolute iodine concentrations, Dual-Energy CT (DECT) promises to add considerable diagnostic information in the field of abdominal oncologic imaging (Agrawal et al., 2014). Iodine maps contain quantifiable information about tumor vascularity and viability and may be used to evaluate treatment response (Apfaltrer et al., 2012; Chen et al., 2014). Hence, reproducible measurements are essential for further treatment decisions. Similar to the measurement of tumor size, the analysis of iodine uptake has hitherto relied on measurements in 2 dimensions (2D) (Zhang et al., 2010). However, recent technological advances enable three-dimensional (3D)-measurements. The aim of this study was to compare interobserver reproducibility of a semiautomatic tool for 3D-segmentation and quantification of iodine uptake in hepatic colorectal metastases with 2D-measurements in DECT.en_GB
dc.language.isoenen_GB
dc.publisherESR - European Society of Radiologyen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectAbdomen -- Cancer -- Diagnosisen_GB
dc.subjectLiver -- Cancer -- Diagnosisen_GB
dc.subjectAbdomen -- Cancer -- Tomographyen_GB
dc.subjectLiver -- Tomographyen_GB
dc.subjectDual energy CT (Tomography)en_GB
dc.subjectIodine in the bodyen_GB
dc.titleIncreased reproducibility of semiautomatic 3D-segmentation over 2D-measurements for quantification of specific iodine uptake of hepatic colorectal metastases in dual-energy CTen_GB
dc.typeconferenceObjecten_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.bibliographicCitation.conferencenameEuropean Congress of Radiology-ECR 2016en_GB
dc.bibliographicCitation.conferenceplaceVienna, Austria, 02-06/03/2016en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1594/ecr2016/C-2308-
dc.publication.titleEuropean Congress of Radiology-ECR 2016en_GB
Appears in Collections:Scholarly Works - FacM&SCRNM



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.