Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/117643
Full metadata record
DC FieldValueLanguage
dc.date.accessioned2024-01-19T10:56:17Z-
dc.date.available2024-01-19T10:56:17Z-
dc.date.issued2023-
dc.identifier.citationSciberras, R. (2023). A preliminary study on the design, fabrication and application of a 3D-printed paediatric bladder phantom for optimisation of nuclear medicine procedures (Bachelor's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/117643-
dc.descriptionB.Sc. (Hons)(Melit.)en_GB
dc.description.abstractBackground: Ectopic kidneys often deviate from their normal position, affecting accurate differential renal function measurements in conventional renograms. Misdiagnosis is common with a single posterior detector. Existing literature recommends using two detectors, one anterior and one posterior to the patient, to obtain the geometric mean. Literature also states that reliable dosimetry in medical physics requires measurements on anthropomorphic phantoms with known activity concentration. This can be done using 3D printing techniques to create tissue-mimicking phantoms. Objectives: This research study investigates the application and feasibility of 3D printing in Nuclear Medicine, specifically focusing on the development and evaluation of a patient specific anthropomorphic paediatric phantom. This study also explores the differential renal function measurements in the presence of a pelvic kidney as well as the effect the bladder has on this kidney. Research Methodology: This research was conducted by designing and fabricating the anthropomorphic phantom, injecting it with Technetium-99m, and scanning using a gamma camera having two detectors, one anterior and the other posterior to the phantom. Results: The results obtained from the gamma scans were evaluated using specialised software and surprisingly, contrary to what was reviewed in the literature, no significant differences in differential renal function measurements were observed between normal and pelvic kidneys. Nonetheless, according to this study, the close proximity of the bladder to the pelvic kidney does influence the detected gamma counts. Conclusions: This study demonstrated the feasibility of injecting radioisotopes into 3Dprinted phantoms, without posing any risks, thereby showcasing their potential for use in Nuclear Medicine. The absence of significant differences in the differential renal function between normal kidneys and kidneys with a pelvic kidney could potentially be attributed to the thinness of the paediatric pelvic bone. The thinner pelvic bone found in children might have contributed to the preservation of accurate renal measurements. Recommendations: It is suggested that the study should be repeated with an adult phantom to compare the findings with the paediatric population. With the introduction of 3D printed phantoms, Medical Physicists need to establish Quality Assurance tests for such phantoms ensuring they are up to standards according to the current European protocols.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectKidneys -- Modelsen_GB
dc.subjectPelvis -- Modelsen_GB
dc.subjectPhantoms (Radiology)en_GB
dc.subjectThree-dimensional printingen_GB
dc.subjectPediatricsen_GB
dc.subjectNuclear medicineen_GB
dc.titleA preliminary study on the design, fabrication and application of a 3D-printed paediatric bladder phantom for optimisation of nuclear medicine proceduresen_GB
dc.typebachelorThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Science. Department of Physicsen_GB
dc.publisher.departmentFaculty of Health Scienceen_GB
dc.description.reviewedN/Aen_GB
dc.contributor.creatorSciberras, Rodianne (2023)-
Appears in Collections:Dissertations - FacHSc - 2023
Dissertations - FacSci - 2023
Dissertations - FacSciPhy - 2023

Files in This Item:
File Description SizeFormat 
2308HSCMPH301300010916_1.PDF
  Restricted Access
4.9 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.