Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/121666
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPinhata-Baptista, Otavio Henrique-
dc.contributor.authorda Silva, Felipe Monteiro-
dc.contributor.authorGoulart Gil Choi, Isabela-
dc.contributor.authorCortes, Arthur R. G.-
dc.date.accessioned2024-05-02T05:59:03Z-
dc.date.available2024-05-02T05:59:03Z-
dc.date.issued2024-
dc.identifier.citationPinhata-Baptista, O. H., da Silva, F. M., Choi, I. G. G., & Cortes, A. R. G. (2024). Four-millimeter implants supporting unsplinted metal-ceramic screw-retained crowns in posterior jaw: a retrospective case series. Scientific Letters, 1(1), 3.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/121666-
dc.description.abstractLittle is known about the clinical performance of unsplinted crowns supported by 4-mm im-plants. The objective of this investigation was to evaluate the clinical performance of extra-short implants supporting single restorations. A retrospective cross-sectional study design was used and included patients treated with 4-mm implants between 2014 and 2017. The influence of crown-to-implant ratio (CI ratio), age, sex, bleeding on probing, type of arch, implant diameter, occlusion antagonist and functional loading time on mesial and distal marginal bone loss around the implants were analyzed using univariate and multivariate linear regression models. A total of 27 cone morse dental implants with 4 mm in diameter was evaluated after a minimum post-loading time of 12 months. One implant was lost after loading, lead-ing to an implant survival percentage equal to 96,3%. No other failure conditions were observed. From the variables analyzed herein, only CI ratio, functional loading time and sex were significantly associated with marginal bone loss on the mesial site of implants; and only CI ratio, functional loading time and bleeding on probing were associated with marginal bone loss on the distal site of implants. The present results suggest that 4-mm implants placed in the posterior maxilla and mandible to support unsplinted metal-ceramic screw-retained crowns may be a very promising alternative in order to enable the rehabilitation of posterior edentulous patients, who are unable or unwilling to undergo bone grafting procedures with high morbidity. However, further prospective long-term studies should confirm if this is a viable treatment option.en_GB
dc.language.isoenen_GB
dc.publisherIUCS-CESPU Publishingen_GB
dc.rightsinfo:eu-repo/semantics/openAccessen_GB
dc.subjectOsseointegrationen_GB
dc.subjectCrowns (Dentistry)en_GB
dc.subjectImplants, Artificialen_GB
dc.subjectDental implantsen_GB
dc.titleFour-millimeter implants supporting unsplinted metal-ceramic screw-retained crowns in poste-rior jaw areas : a retrospective case seriesen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.48797/sl.2024.122-
dc.publication.titleScientific Lettersen_GB
Appears in Collections:Scholarly Works - FacDenDS



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.