dc.description.abstractBackground: The hospital where this study was carried out is in possession of two whole-body MRI Siemens scanners (Siemens Magnetom Aera (2012) and Siemens Magnetom Avanto (2007), Erlangen, Germany). Both machines have field strength of 1.5T but have significant differences between them, namely: the bore size, field of view restrictions and radio frequency receive coils. Despite these differences, the two machines are currently being operated using the same protocol which indicates that the latter may not be optimised for both scanners. Objectives: The primary purpose of this study was to measure and compare Signal to noise ratio (SNR) and SNR uniformity of the two systems. A second objective was to evaluate the different methods of SNR measurement found in MRI literature. Research Design: SNR measurements were carried on spin echo (SE) images using the head coils and combination of body-spine coils. SNR evaluation was carried out on region-of-interests (ROIs) on both phantom and anonymised patient images. The American College of Radiology (ACR) phantom and five cylindrical fluid filled phantoms provided by the manufacturer were used to obtain phantom images. For patient images, neurological and prostate images were used for evaluation of SNR. Different approaches of SNR measurement were compared in phantom measurements with the gold standard multiple-acquisition method (MAM). In patient images only single-image methods could be applied. Results: Deviations from the gold standard were noted. For the head phantom measurements, the Aera produced higher SNR than the Avanto with the highest being 166% and lowest 131%. For the body phantom, SNR values from the Aera were again higher, the highest being 132% and lowest 103%. In general, t-testing indicated that the Aera produces significantly (P<0.05) higher SNR than the Avanto for various ROIs on patient images. Conclusions and recommendations: The Aera scanner produced higher SNR than the Avanto for both phantom and patient images. Based on the assumption that the Avanto SNR is adequate, it is recommended that the increased SNR of the Aera should be used to optimise scanning protocols allowing shorter scan times or improvements in resolution.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectMagnetic resonance imagingen_GB
dc.subjectMedical instruments and apparatusen_GB
dc.titleA comparison of SNR of two generations of Siemens 1.5T MRI scanners and their associated RF phased array coilsen_GB
dc.typemasterThesisen_GB
dc.rights.holderThe copyright of this thesis/dissertation belongs to the author. The author’s rights in respect of this work are as defined by the Copyright Act (Chapter 415) of the Laws of Malta or as modified by any successive legislation. Users may access this full-text thesis/dissertation and can make use of the information contained in accordance with the Copyright Act provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Health Sciences. Department of Medical Physicsen_GB
dc.description.reviewedN/Aen_GB
dc.contributor.creatorVella, Nolan
Appears in Collections:Dissertations - FacHSc - 2015
Dissertations - FacHScMP - 2015

Files in This Item:
File Description SizeFormat 
15MSMP08.pdf
  Restricted Access
5.04 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.