Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/18944
Title: | On the suitability of hexagonal honeycombs as stent geometries |
Authors: | Mizzi, Luke Attard, Daphne Casha, Aaron Grima, Joseph N. Gatt, Ruben |
Keywords: | Honeycomb structures Finite element method Stents (Surgery) Materials -- Mechanical properties |
Issue Date: | 2014-02 |
Publisher: | Wiley-VCH |
Citation: | Mizzi, L., Attard, D., Casha, A., Grima, J. N., & Gatt, R. (2014). On the suitability of hexagonal honeycombs as stent geometries. Physica Status Solidi (b), 251(2), 328-337. |
Abstract: | It is a well-known fact that the mechanical properties of coronary stents are defined mainly by two components, the constituting material and the design pattern of the stent itself. The latter especially has attracted the interest of entrepreneurs and scientists alike with a plethora of patents being issued for numerous stent designs. Despite this widespread interest, the suitability of said designs are seldom studied. Accordingly, in this work we have investigated the properties of stent designs based on the hexagonal honeycomb geometry. Stent patterns based upon re-entrant, non re-entrant, and hybrid honeycomb geometries were studied with respect to their behaviour at extremely high strains using Finite Element Analysis. The data collected indicates that although the non re-entrant and hybrid geometries may be more suited to stent designs than the re-entrant geometry in terms of tolerance to high strains, none of these systems convey all the ideal properties desired in a stent, even if the former two have the potential of exhibiting some of them. |
Description: | This work has been funded through the Malta Council for Science and Technology through the R&I-2011-024 Project (Smart Stents). The authors would like to thank the industrial partners involved in this project, HM RD Ltd. part of the Velsud Group, and Tek-Moulds Precision Engineering Ltd. Equipment purchased through the European Regional Development Fund, Project ERDF-080 ‘A Supercomputing Laboratory for the University of Malta’, has also been used. |
URI: | https://www.um.edu.mt/library/oar//handle/123456789/18944 |
Appears in Collections: | Scholarly Works - FacHScFSEH Scholarly Works - FacM&SAna Scholarly Works - FacSciChe Scholarly Works - FacSciMet |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
On the suitability of hexagonal honeycombs as stent geometries.pdf Restricted Access | On the suitability of hexagonal honeycombs as stent geometries | 2.28 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.