Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/18962
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGatt, Ruben-
dc.contributor.authorBrincat, Jean-Pierre-
dc.contributor.authorAzzopardi, Keith M.-
dc.contributor.authorMizzi, Luke-
dc.contributor.authorGrima, Joseph N.-
dc.date.accessioned2017-05-14T18:30:40Z-
dc.date.available2017-05-14T18:30:40Z-
dc.date.issued2015-02-
dc.identifier.citationGatt, R., Brincat, J. P., Azzopardi, K. M., Mizzi, L., & Grima, J. N. (2015). On the effect of the mode of connection between the node and the ligaments in anti-tetrachiral systems. Advanced Engineering Materials, 17(2), 189-198.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/18962-
dc.description.abstractChiral systems may exhibit auxetic behavior, i.e. they may have a negative Poisson's ratio. This particular property has led to their being studied extensively by several authors. A Finite Elements Study is presented here, investigating the mode of connection between the nodes and ligaments in the anti-tetrachiral structure. The results show that the amount of gluing material used to attach the ligaments to the node will not affect the Poisson's ratio, but may have a large influence on the observed stiffness of the structure (Young's modulus). It is also shown that the stiffness of the glue will have a large effect on the mode of deformation of the chiral system. This change in mechanism was found to effect the stiffness of the structure but not its Poisson's ratios.en_GB
dc.language.isoenen_GB
dc.publisherWiley-VCHen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectChiralityen_GB
dc.subjectFinite element methoden_GB
dc.subjectChemical modelsen_GB
dc.subjectElasticityen_GB
dc.titleOn the effect of the mode of connection between the node and the ligaments in anti-tetrachiral systemsen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1002/adem.201400120-
Appears in Collections:Scholarly Works - FacHScFSEH
Scholarly Works - FacSciChe
Scholarly Works - FacSciMet

Files in This Item:
File Description SizeFormat 
On the Effect of the Mode of Connection between the Node and the Ligaments in Anti-Tetrachiral Systems.pdf
  Restricted Access
On the effect of the mode of connection between the node and the ligaments in anti-tetrachiral systems3.5 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.